935 Uppsatser om Directional earth-fault protection - Sida 1 av 63
RCC-Jordfelsskydd, mätmodul för övertonsanalys
The majority of all power cuts that affects individuals and communities are caused by earth faults on the power transmission lines at 10kV and 20kV level [1]. If these power cuts could be eliminated, less disturbances and interrupts would lead to large amounts of money savings.Swedish Neutral has developed such a protection system. When an earth fault occurs power is injected into the neutral point of the transformer. The RCC (Residual Current Compensation) protection calculates a compensation current exactly 180 degrees out of phase to the fault current. Doing this, the voltage at the fault location becomes very close to zero, without affecting the power transmission.The protection system can only compensate automatically for the fundamental frequency (50Hz), and manually for the 3rd, 5th, 7th and 9th harmonics.
Nollföljdsmodellering av transformator-Beräkningar av följdproblem vid ökad kablifiering på mellanspänningsnivå
Historically transformers with system earth equipment have been modeled as open circuits in zero sequence. This approximation has been satisfying, but lately it has been discovered that equipment on one side of the transformer have responded to faults that occurred at the other side. Most of these problems took place when the majority of the system on the secondary side of the transformer contained cables. These findings have led to questioning whether or not the former model of the transformer in zero sequence is correct. This report investigates if it is necessary to represent the transformer in zero sequence in another way than it is usually done today.
Analys och förbättringsförslag för riktkopplardesign
Ericsson develops a new stripline directional coupler. Its design is described in appendix B and differs from the directional couplers Ericsson uses in current products. The new directional coupler will be used for transmission power measurement in future UMTS 3G base stations.The most important parts of directional coupler theory are presented. It is necessary to study this theory to understand how the coupler works and how it should be designed to get good performance.Optimal directional coupler termination component values to get high directivity and broad directivity bandwidth have been investigated.The trim screws trim ranges have been studied.A simple analysis of serial production performance when termination component tolerances are taken into consideration has been done.The resistance components reactive (inductive/capacitive) characteristics at 2.14 GHz have been analyzed.The directivity performance limitations of the directional coupler, when Ericsson?s band pass filter is connected, are investigated.Design changes leading to better performance are proposed.
Automation i Distributionsnät
As a part of Göteborg Energi?s work towards a smarter electric grid, the company has chosen to investigate the possibilities of automation in their middle voltage grid. In Europe, there are example cases where these technologies already are installed which many articles on the CIRED conference 2011 proved. Netcontrol Oy in Finland has, together with Tekla, created an automated SCADA system that Vattenfall in Finland today uses. The grid mainly consists of 10 kV open loop fed city grid and this automation is mainly designed for this type of grid.
Analys av fördelningssystem för bostadshus
The purpose of this project is to analyze earthing systems for houses. By practical measurements and theoretical analyzes consequences of possible faults, that can occur within the facility and in the low-voltage distribution network, is illustrated. The reason for this project is that nowadays one has to arrange with a main equipotential bonding system for buildings. Apart from that, if necessary, bathrooms must be provided with a supplementary equipotential bonding system.The practical measurements verify that potential differences in facilities may be due to voltage drops in the PEN conductor between the origin of the electrical installation and the power transformer.Based on the theoretical analyzes of possible faults, it is considered that the requirement for supplementary equipotential bonding systems for bathrooms in most cases can be questioned, when basic insulation, fault protection, residual current devise and main equipotential bonding system already provides an adequate level of protection.A PEN conductor loss may result in a situation where metallic parts attached to the equipotential bonding system starts working as earth electrodes. Equipotential bonding system may also increase the incidence of stray currents. If TN-C-S systems is provided with a local connection to earth a redundant system against PEN conductor loss is obtained.
Vinkelfelet i mätkretsens påverkan på riktade jordfelsskydd
Utfört examensarbete undersöker vinkelfelet i mätkretsen för riktade jordfelsskydd och hur det påverkar dess felbortkoppling. Uppkomna vinkelfel i mätkretsen kan påverka det riktade jordfelsskyddet så att verklig felström och uppmätt felström inte stämmer överens, vilket kan leda till uteblivna eller obefogade felbortkopplingar. Vattenfall ställer krav på att vinkelfelet får uppgå till max ±2 grader för mätkretsen. Eftersom vinkelfelet i många fall har en hög påverkan på jordfelsskyddets noggrannhet undersöks vad Vattenfalls vinkelkrav egentligen innebär. Största orsaken till vinkelfelet uppstår oftast i strömtransformatorn och därför undersöks hur mycket två strömtransformatorer med olika klassificeringar som är vanliga i elnätet påverkar vinkelfelet i mätkretsen.Jordfel är det vanligast uppkomna felet i mellanspänningsnät och dess storlek beror till stor del på hur mycket kapacitivt bidrag som finns på linjerna samt värdet på nollpunktsresistorn.
Framtagning av reläskyddsinställningar för en transformatorstation
A substation must be properly protected against lightning and other external effects to the equipment in the station or staff, for that we use relay protection. They should also protect against internal errors which may occur as ground faults. There are different types of protection relays, but most common are overcurrent-, distance-, residual current- and differential protection.The purpose of this thesis was to deepen our knowledge of relay protection and to use the theoretical knowledge we got from the university studies in the work process. In the process we discovered which parameters were the most essential and calculated these for all relay protections on the substation. We also carry out a comparison between two brands of relay protection, ABB and Alstom.During our work we will test and simulate the over-current relays in a program called NEPLAN, the program will also calculate the fault currents.
Quartzene i gips : Densitet och hållfasthet
A substation must be properly protected against lightning and other external effects to the equipment in the station or staff, for that we use relay protection. They should also protect against internal errors which may occur as ground faults. There are different types of protection relays, but most common are overcurrent-, distance-, residual current- and differential protection.The purpose of this thesis was to deepen our knowledge of relay protection and to use the theoretical knowledge we got from the university studies in the work process. In the process we discovered which parameters were the most essential and calculated these for all relay protections on the substation. We also carry out a comparison between two brands of relay protection, ABB and Alstom.During our work we will test and simulate the over-current relays in a program called NEPLAN, the program will also calculate the fault currents.
Från myt till Ptolemaios: Geografin under antiken
This paper deals with the development of scientific geography during Antiquity from its mythical background before the seventh century BC to Claudius Ptolemy during the second century AD. The main focus is on questions concerning the shape of the earth, its place in the universe, size and mapping of the earth. Already before 400 BC, the idea of the earth as a globe was firmly estabished. During classical time, Aristotle used empirical and rational arguments to prove that the earth was a sphere and that it was situated motionless in the center of the universe. In the third century BC, the first reasonably correct measurements of the circumference of the earth was carried out by Eratosthenes.
Felisolering av hytt- och chassikomponenter på tunga fordon
This master of science thesis is focusing on how the fault handling on hardware connected toa control unit on a Scania vehicle is working. To the hardware counts buttons levers, sensorsand CAN. The work has been concentrated upon how the fault handling is working and if it ispossible to find any new fault modes.The control unit that has been studied is called the Coordinator and is the core in Scanias threenetworks of control units. The Coordinators work is to transmit messages between the threenetworks and to process signals from buttons, levers and sensors. The values is then usedinternally or is sent to other control units on the CAN networks.
Modellering av supra och englaciala vattenkroppar detekterade i markradar data från Grönland
Earth science is a dynamic system science that explores the structures and processes of the earth. Knowledge about the earth is important for citizens since the science is a vital part in the sustainable development of the society. Without good basic knowledge the citizens don?t have the possibility to anticipate in the questions and decision-making that concerns e.g. anthropogenic climate change. In the Swedish school system earth science is not an independent subject until academically studies at the University?s.
Geovetenskaplig analfabetism i Sverige ? En undersökning av allmänhetens och beslutsfattarnas kunskaper
Earth science is a dynamic system science that explores the structures and processes of the earth. Knowledge about the earth is important for citizens since the science is a vital part in the sustainable development of the society. Without good basic knowledge the citizens don?t have the possibility to anticipate in the questions and decision-making that concerns e.g. anthropogenic climate change. In the Swedish school system earth science is not an independent subject until academically studies at the University?s.
Jordtäckta hus : Energiberäkningar och kostnadskalkyler på ett jordtäckt hus i Malmö
With rising energy prices and the threat of climate change, energy costs and energy savings havebecome a central and important part in building. Therefore it is interesting to explore different andnon-conventional methods of energy conservation. Building Earth sheltered houses is such a method.Earth provides good insulation and provides the ability to both reduce the total heating needs and toreduce the maximum power demand. The aim of this study was to construct a house in Malmö and seeif Earth sheltered houses can be a cost effective alternative for the construction of sustainable andenergy-efficient houses.Previous studies have shown that Earth sheltered houses have reduced their power requirement with upto 25% and their use of energy with 10%. Numerical calculations in Comsol Multiphysic 4.2, wasperformed on a house with different degrees of earth covering.
Hjälpkraftsystem med två lågspänningsnivåer
Because of increasing demand of power on Malmbanan the capacity of the existing wires which supply the trains must be increased. This increases the stress on the existing poles and for this reason the system for supplying the loads along the railway is to be removed from the poles and be replaced by some other system. This thesis is a study on a two-level low voltage (1 kV and 0.4 kV) electrical system with the aim to investigate if it can be an alternative to the system used today taking into account the voltages, fault currents and costs.In this thesis the following tasks have been performed:? Gathering of data? Description of basic theory? Loadow and fault current calculations of the system with MATLAB? Life Cycle Cost estimate of the system? Analysis and conclusions from the resultsThe results show that the new system can be an alternative to replace today's system. The simulations and calculations show that the voltage drop is at an acceptable level and that the fault currents are large enough to supply a safe disconnection if a fault occurs at the far end of the system..
Översyn av vattenskyddsföreskrifter med tillhörande vattenskyddsområde i Hallstahammars kommun. : Vilka revideringsbehov finns?
Water is an important food and an important natural resource. In order to protect these are the Environmental Code and the EU directive given to water protection and related water protection regulations will be established for all water sources until 2010. Those who will prepare a water protection and related water protection regulations is the municipality or person responsible for water supply. The person then decides and declares the area as water protection and related water protection regulations are municipal or provincial government. The idea of creating a water protection is to protect the water supply and the body of water against pollution caused by point sources, diffuse sources and accidents combined.